Important Info

Featured Sponsor

Become an Author

GeoPrac.net is a community site, we are only as good as the content our members contribute! Whether it's a one time contribution, or a monthly or quarterly article, please consider becoming an author!

Latest Comments in...

San Francisco Millennium Tower Has Settled 16 Inches
Misrepresents actual foundation geometry. Photos show deep excavation to ne
New FHWA Soil Nail Manual Addresses LRFD, Hollow Bars
Good evening from Barcelona, Spain. I am witting to you because of I am le
Engineering Geologists vs Geological Engineers vs Geotechnic
Geological engineer from Spain (looking for job smiley geoengineer.martin@gmail
A Whole Lotta Shakin' Goin' On: Center for Geotechnical Mode
Randy, While the UC Davis lab is impressive I believe the USACE Centrifuge
Content
New FHWA Soil Nail Manual Addresses LRFD, Hollow Bars PDF Print E-mail
Written by Randy Post   
Sunday, 12 April 2015 22:05

GEC7_2015_coverSince March of 2003, the FHWA’s Geotechnical Engineering Circular Number 7 (GEC No. 7) has been the standard reference document for design and construction of soil nail retaining walls in roadway applications, and really in all applications. The FHWA has released an updated version of this manual as of February of 2015.  This new version is still called GEC No. 7, but now titled “Soil Nail Walls Reference Manual.”  You can download the document from the FHWA’s Geotechnical Engineering website.

I am still in the process of working through the manual, but one of the major changes is the addition of the implementation of the Load and Resistance Factor Design (LRFD) platform. This will have an implication on all future soil nail walls for roadway projects.

The manual also appears to have removed example problems solved using SNAILZ software (by CalTrans) in favor of the FHWA’s own Soil Nail Analysis Program (SNAP) 2 software. I guess we’re going to have to get familiar with that software as well.  I’m strongly considering looking into SNAIL Plus by DeepExcav, a commercial product.  I’ve seen demos before, and have been very impressed.

Finally, I was very curious to see what they would say about hollow bar soil nails.  They review some of the work done in the last 5 years or so done by the FHWA and ADSC.  If I understood correctly, it appears that they are saying that because of the uncertainties regarding damage to corrosion protection during installation, they are still not recommending hollow bar nails for roadway applications, except if the ground conditions are non-aggressive and if you use sacrificial steel.  I suppose that at least opens the door to this technology for collapsing ground situations.  

Hits: 4369
Trackback(0)
Comments (1)add comment

Agus said:

0
...
Good evening from Barcelona, Spain.

I am witting to you because of I am learning to use the software SNAP-2. So, I have a question for you in caso of you have managed with the software. Here I go, do yo know how the program calculate the lenght where the tensile load diagram in the nail finishes?. I mean, in the upper nails the tensile load finishes at the end, but in the lower nails, the tensile diagram finishes before the end of the nail. I don't know how the program work out that lenghts.

Please, if you could write to me I would be very pleased if you know the answer.

Thank you very much

Agus
 
March 15, 2016 | url
Votes: +0

Write comment

security image
Write the displayed characters


busy
Last Updated on Tuesday, 14 April 2015 05:54